Lucene search

K

GE Healthcare Security Vulnerabilities

cve
cve

CVE-2024-1486

Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound...

7.4CVSS

7.3AI Score

2024-05-14 04:15 PM
21
cve
cve

CVE-2024-1630

Path traversal vulnerability in “getAllFolderContents” function of Common Service Desktop, a GE HealthCare ultrasound device...

7.7CVSS

7.2AI Score

2024-05-14 05:15 PM
23
cve
cve

CVE-2024-1628

OS command injection vulnerabilities in GE HealthCare ultrasound...

8.4CVSS

8AI Score

2024-05-14 04:16 PM
25
cve
cve

CVE-2024-27110

Elevation of privilege vulnerability in GE HealthCare EchoPAC...

8.4CVSS

7.3AI Score

2024-05-14 06:15 PM
23
cve
cve

CVE-2024-27107

Weak account password in GE HealthCare EchoPAC...

9.6CVSS

7.4AI Score

2024-05-14 05:15 PM
27
cve
cve

CVE-2024-1629

Path traversal vulnerability in “deleteFiles” function of Common Service Desktop, a GE HealthCare ultrasound device...

6.2CVSS

7.2AI Score

2024-05-14 05:15 PM
20
cve
cve

CVE-2024-27106

Vulnerable data in transit in GE HealthCare EchoPAC...

5.7CVSS

7.2AI Score

2024-05-14 05:15 PM
22
cve
cve

CVE-2024-27109

Insufficiently protected credentials in GE HealthCare EchoPAC...

7.6CVSS

7.2AI Score

2024-05-14 05:15 PM
22
cve
cve

CVE-2024-27108

Non privileged access to critical file vulnerability in GE HealthCare EchoPAC...

6.8CVSS

7.1AI Score

2024-05-14 05:15 PM
21
cve
cve

CVE-2017-14008

GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected...

9.8CVSS

9.6AI Score

0.002EPSS

2018-03-20 04:29 PM
31
4
cve
cve

CVE-2017-14006

GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected...

9.8CVSS

9.6AI Score

0.004EPSS

2018-03-20 04:29 PM
25
cve
cve

CVE-2017-14002

GE Infinia/Infinia with Hawkeye 4 medical imaging systems all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected...

9.8CVSS

9.6AI Score

0.002EPSS

2018-03-20 04:29 PM
21
4
cve
cve

CVE-2017-14004

GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected...

9.8CVSS

9.6AI Score

0.004EPSS

2018-03-20 04:29 PM
39